Switch Settings Installation
SPARC/CPU56T 47
Switch DescriptionNo.
2 Enable termination for SCSI 2
OFF (default): Termination enabled
ON: Termination disabled
3 Enable termination for SCSI 3 (on I/O−board, if applicable)
OFF (default): Termination enabled
ON: Termination disabled
4 Reserved
SW4 1..2 VME Slot 1 Detection
SW4−1 OFF (default): Automatic VMEbus slot 1 detection enabled
SW4−1 ON and SW4−2 OFF: VME slot 1 function enabled
SW4−1 ON and SW4−2 ON: VME slot 1 function disabled
3 External VMEbus SYSRESET function
OFF (default): VMEbus SYSRESET generates on−board RESET
ON: VMEbus SYSRESET does not generate on−board RESET
4 VMEbus SYSRESET generation
OFF (default): On−board reset is driven to VMEbus SYSRESET
ON: On−board reset is not driven to VMEbus SYSRESET